REC MODE:
This option determines the recording mode to be recorded when the FTP function occurs.
There are 2 levels of recording mode to choose: ALARM REC and ALL REC .
ALARM REC : Only to capture the alarm -event recorded video.
ALL REC : To capture all the recorded video.
REC RATE:
This option determines the recording rate when the FTP function occurs. There are 4 levels of
recording rates to choose from: 1 F / 1 S, 1 F / 10 S, 1 F / 30 S and 1 F / 60 S .
ACCOUNT:
This option is used to configure the FTP account settings. This is required for the purpose of
making an FTP connection. Please consult with a qualified MIS professional to configure it.
FTP IP : Every FTP server has to own an IP address to be identified on the network.
Input the IP address of the FTP server.
USER : Input the FTP user name (Login Name).
PASSWORD : Input the FTP password (Password).
PATH : Input the upload path while doing the FTP.
FTP ACCOUNT
FTP IP : 192.168.001.128
USER : [ dvr ]
PASSWORD : [ 00000000 ]
PATH : [ /dvrvideo ]